A systems-engineering workspace for an illustrative inertial fusion energy plant. Connect pulsed fusion production to heat recovery, fuel supply, plant loads and electrical export; identify the evidence needed before a design assumption becomes a requirement.
Select a complete preset, edit the power, geometry, cooling and fuel inputs, then Calculate design. Inspect the power ledger, compare gain/Q sensitivity, and save or reload your design. All values are illustrative assumptions; efficiencies and probabilities are fractions.
Operating net (MW electric)
Calendar average (MW electric)
Annual net energy (GWh)
Annual tritium consumed (kg)
Separate power boundaries; thermal and electrical bars are not additive. Net electricity subtracts the declared electrical loads once.Change target gain with all other power assumptions fixed. This curve describes the budget, not a prediction of ignition or confinement.
Trade-study numerical valuesAll calculated design results and units
Copyable export preview
Component-sizing summary and thermal model transfer
Coolant flow (kg/s)
Exchanger area (m²)
Pump electricity (MW)
Buffer capacity (J/K)
All calculated component allocations
Flow and fuel consumption refer to the declared production/full-power state. Pump demand and local heat allocations are parts of existing plant ledgers, not automatically added loads. The buffer neglects losses and finite transfer rate. The ICF buffer uses one recovered event; surface heat is a separate subset of the fusion source.
Mission and system boundary
Produce useful average electrical output from repeated fusion events while maintaining fuel accounting, chamber readiness and serviceable equipment. Driver-delivered energy and target gain are scenario inputs; this page does not calculate a target implosion.
Concept study for electricity generation. All calculator presets are hypothetical design assumptions; positive calculated export is a budget result, not validated reactor performance.
The boundary encloses the reactor, fuel cycle, blanket, cooling, power conversion, driver or heating equipment, controls and services. Inputs are electricity, make-up fuel, cooling resources and replacement components. Outputs are net electricity, rejected heat, recovered/exhausted material and maintenance demands. Startup, burn/event production, standby, trip recovery and maintenance are distinct operating states.
Confinement and the design boundary
Inertial confinement holds a reacting fuel state for a short time through its inertia. A plant-level model starts with an independently supported energy yield per event and couples it to event rate and equipment duty. A high target gain does not establish efficient electrical input, repeatable chamber operation or fuel self-sufficiency. LLNL defines target gain using energy delivered to the target; its ignition explanation establishes that boundary.
Repetition is a system constraint
Allocate a common event clock to driver recovery, qualified target supply, chamber recovery and diagnostics. The slowest ready subsystem limits useful throughput. Use effective gain that includes nonproductive events, or a usable-event rate, and state which convention was chosen; do not penalize the same failed event twice.
Driver and thermal trade
Increasing driver efficiency reduces recirculating demand. Increasing rate scales both fusion output and driver demand, while chamber thermal duty, lifetime and replacement burden also change. The calculator holds these inputs independent for sensitivity analysis; feasibility must be established by integrated tests. The DOE Fusion S&T Roadmap identifies efficient repetitive drivers, chamber response and integrated fusion-energy technology as development needs.
Functional architecture and subsystem interfaces
Electrical supplyDriver input and plant services
Fusion driverDelivered energy per event
Target and chamberAssumed gain and repetition rate
Blanket and coolantRecoverable thermal power
Power islandGross electricity → net export
The arrows follow energy conversion. Fuel, diagnostics, protection and maintenance close additional loops; they are not represented by a single energy arrow.
Driver and power conditioning
Allocate delivered energy, electrical efficiency, repetition duty, optical/electrical interfaces and maintainability. Driver waste heat and power conditioning are plant loads.
Interface: Grid supply → driver; delivered energy and timing → chamber.
Target supply and event readiness
Treat qualified target supply, delivery reliability, diagnostics readiness and chamber recovery as a single repetition-chain constraint. Account for unsuccessful events in the effective mean gain or usable-event rate.
Interface: Production throughput → delivery; readiness/permissive → driver.
Chamber and lifetime
Define pulsed heat/debris handling, recoverable heat fraction, component replacement and reset time without equating a single successful event with sustained operation.
Interface: Event energy → thermal recovery; recovery time → maximum event rate.
Fuel cycle and inventory
Supply, recover and account for fuel across the reactor, processing equipment and storage. Define start-up inventory, processing delay, losses and reserve.
Interface: Fuel mass flow, purity and inventory → reactor; recovered exhaust → processing.
Blanket, shielding and primary cooling
Allocate heat recovery, breeding performance, material lifetime and service access together. Track penetrations and replacement outages as system constraints.
Convert recoverable heat into gross electrical output, then subtract every plant load. Allocate coolant temperature/pressure requirements and environmental heat-sink capacity.
Separate performance feedback from independent protection functions. Define measured quantities, quality flags, timing, interlocks and the response to unavailable sensors.
Design replaceable modules, inspection access, lifting interfaces and outage schedules as part of the concept. Distinguish operational duty from plant availability.
Interface: Condition and dose information → maintenance plan; spare modules and outage duration → availability.
Confinement, waste and site services
Define fuel-containment boundaries, cooling continuity, monitoring, material handling and utility dependencies for normal operation and fault states.
Interface: Heat, inventory and service demands → site; monitoring and condition status → operations.
Interactive plant power trade study
The operating-point inputs are now together in the interactive design worksheet. Efficiencies are fractions, not percentages. Values update immediately and can be downloaded as JSON. The equations are an algebraic system budget; this is separate from the PDE model list.
Capture applies to fusion energy only. Recovery of auxiliary/driver heat and blanket energy multiplication are omitted. Other loads include pumps, cryogenics where applicable, fuel handling, controls and balance-of-plant services; driver/heating demand is subtracted separately. Standby replaces production loads in nonproducing periods. Duty and availability do not change the stated operating fusion power. Annual energy uses an illustrative 8760-hour year. Thermal rejection is recovered heat minus gross electricity; additional unrecovered fusion heat and electrical losses still require a full site heat-rejection study.
The input bounds on the form aid editing; physically infeasible positive values can still be entered. The calculator checks finite values and fraction ranges but does not validate a driver, confinement scenario or component design.
Worked design-point calculation
Assume Edriver=2 MJ/event, G=70, f=5 Hz, ηdriver=.15, ηcapture=.90 and ηthermal=.40. These are illustrative inputs, not measured performance of a facility.
Fusion energy per event = 70×2 = 140 MJ; operating fusion power = 140×5 = 700 MW.
Driver electricity = (2×5)/.15 = 66.6667 MW. Add other plant loads of 30 MW: operating net = 155.3333 MW.
At availability .75 and standby load 5 MW, average export = .75×155.3333−.25×5 = 115.25 MW, or 1009.59 GWh/year.
Operating break-even follows G > [1/ηdriver + Pother/(fEdriver)]/(ηcaptureηthermal) = 26.8519. The threshold increases further if annual standby demand is included. At G=10, fusion production continues but operating electrical output is negative.
Fuel consumption and self-sufficiency
For D–T fusion, each 17.6 MeV reaction consumes one tritium nucleus. With Ef=17.6×10⁶×1.602176634×10⁻¹⁹=2.819830876×10⁻¹² J:
Reaction rate = Pfusion(W) / Ef(J) [reactions/s]
Tritium burn rate = reaction rate × 5.008×10⁻²⁷ [kg/s]
At 1 GW fusion: approximately 1.776×10⁻⁶ kg/s
= 0.1535 kg per full-power day.
This is consumed fuel, not circulating fuel throughput. A plant inventory model must include unburned recovered fuel, breeding and extraction delays, decay, losses, startup stock and reserve. No fixed breeding-ratio margin is assumed here. Demonstrate recovery and inventory balance over the operating schedule rather than treating a breeding ratio alone as proof of self-sufficiency.
Connect power to coolant and lifetime requirements
That arithmetic allocates a flow requirement for an assumed fluid heat capacity and temperature rise. It does not establish pressure drop, allowable temperature, heat-transfer coefficients, corrosion or material lifetime. Iterate the electrical budget with coolant pumping, achievable cycle efficiency and maintenance outages.
ICF design basis and load cases
The baseline delivers 2 MJ to each target, assumes gain 70, and produces 140 MJ fusion energy at 5 productive events/s. The 700 MW fusion power is a time average during production; recovered heat, gross electricity and net export belong to separate boundaries.
Allocation
Baseline
Design consequence
Event source
140 MJ/event; 0.2 s between productive events
Separate deposition-time profiles, component response and average cooling duty.
Normal event, missed event, interrupted sequence, startup, cooling trip and replacement
Assign sources and equipment states to each case.
All numbers are illustrative allocations. Target gain uses the target-energy boundary; plant performance also includes driver electricity and services. LLNL explains the ignition mechanism and target-gain boundary. Gain alone does not specify a wall-load map or repetitive plant capability.
Driver, target chain and chamber design details
Driver modules and utilities
Allocate delivered energy, conversion losses, recovery duty, cooling, alignment interfaces and replaceable optics. Keep charging power and stored energy separate from average grid demand. Define how degraded modules change the qualified event.
Target production and handling
Record qualified-target throughput, acceptance yield, storage residence, thermal condition, delivery confirmation and reject recovery. Interface records carry target/event identity, quality and measured position/timing uncertainty.
Chamber concepts
A solid first wall emphasizes cooling channels, cyclic stress and replaceable armour. A liquid protective surface adds circulation, surface recovery, vapour/debris management and optical-access constraints. Compare concepts using the same energy source and maintenance calendar.
Blanket and radial allocation
Reserve space for protection, heat-recovery/breeding blanket, manifolds, shell, shielding and service access. Beam and diagnostic penetrations affect deposition and breeding coverage. Choose thicknesses from transport, temperature and structural analyses.
Vacuum and optical access
Allocate next-event gas/debris conditions, pumping throughput, connection conductance, recovery time and optics exposure. Put inspection, collection-system servicing and optic replacement into the calendar.
Heat recovery and power island
Track volumetric neutron deposition, prompt surface deposition and driver-equipment heat on distinct paths. Buffer pulses before applying cycle efficiency. Connect achievable coolant temperatures, exchanger approach, pressure drop and material compatibility.
Event readiness and production capacity
Parallel recovery: tcycle ≥ max(tdriver, tchamber, tdelivery, tdiagnostics)
Serial steps on a shared resource: tcycle ≥ sum of their durations
Scheduled rate ≤ 1/tcycle
Productive rate = scheduled rate × productive-event probability
Manufacturing rate = scheduled rate / qualified-target yield
At a hypothetical productive-event probability of 0.95, 5 productive events/s require 5.263 scheduled events/s. A manufacturing yield of 0.90 then requires 5.848 targets/s, approximately 505,263 per production day. Each resource still needs its own serial/parallel cycle analysis.
The original budget charges driver energy at the productive rate. If missed events also consume full driver energy, use the actual fired rate in that ledger: 70.18 MW instead of 66.67 MW here, reducing operating net by 3.51 MW. Do not penalize effective gain again if it already includes misses. DOE’s roadmap identifies repetitive driver–target–chamber integration as a development need.
Worked ICF component allocations
1. Event energy to chamber-surface load
Assume bookkeeping radius r=5 m, surface fraction fs=0.20 and peak factor Kp=2.
A = 4πr² = 314.159 m²
Esurface = fs Efusion = 0.20 × 140 = 28 MJ/event
Surface fluence = Esurface/A = 89.13 kJ/m² per event
Average surface heat flux = 5 × 0.08913 = 0.44563 MW/m²
Allocated peak average flux = Kp × 0.44563 = 0.89127 MW/m²
The surface fraction is an assumed deposition allocation. It is not the neutron energy fraction and is a subset of fusion energy, so do not add it again to the full recovered source. Neutron volumetric deposition, ports, nonuniform loads and debris require spatial analyses. Peak average flux is distinct from pulse peak flux, which needs a deposition-time profile.
2. Buffer capacity from one recovered event
Erecovered = 0.90 × 140 = 126 MJ
Allowable bulk swing = 20 K
Cminimum = Erecovered/ΔT = 6.3×10⁶ J/K
At cp=4000 J/(kg K): participating mass = 1575 kg
Existing thermal-model Ctotal=3×10⁹ J/K → event increment = 0.042 K
This neglects concurrent heat removal. Participating mass depends on transfer timescales; the whole coolant inventory may not respond to a fast surface pulse. The model’s 0.02 s pulse width is an engineering heat-delivery envelope, not the fusion burn duration.
Distribute this loss among power conditioning, driver modules and their cooling. Delivered driver energy also reaches some chamber/escape branch. The original recovered-heat calculator includes fusion energy only, so a complete site ledger must add these branches once.
ICF operating states and recovery
This is a functional design sequence. Equipment analyses and tests must set measured thresholds, timing and independent protection actions.
State
Interfaces to establish
Verification evidence
Utilities and chamber preparation
Cooling, chamber conditions, driver services and fuel ledger.
Readiness measurements and retained heat removal after a production-power interruption.
Event qualification
Accepted target ID, delivery confirmation, diagnostics and chamber permissives.
Missing/stale qualification inhibits the next event; rejected material is accounted for.
Event and measurement
Common event clock, delivered energy, yield estimate and transient recordings.
Measured event ledger; unavailable data is flagged rather than assumed nominal.
Recovery
Chamber condition, equipment recovery, coolant response and next target.
Completion within each resource’s cycle budget, or a reduced/stopped sequence.
Interruption and restart
Driver inhibit, heat removal, inventory accounting and fault records.
Fault-injection tests and renewed readiness qualification.
Module replacement
Access, handling, spares and post-service alignment/leak checks.
Mock-up duration and service restoration close the availability allocation.
At 5 Hz there are 432,000 productive events per operating day and approximately 118.26 million in a 0.75 available, 8760-hour year. Use event count, deposited energy, neutron exposure and measured degradation together when allocating replacement intervals.
Coolant, heat exchanger and thermal-model design
Use the current recovered thermal power to size a first-pass flow and exchanger duty. Then close hydraulic pressure drop, temperature-dependent properties, materials, corrosion, tritium compatibility and operating transients. These worksheets use constant properties and do not choose a coolant.
1. Sensible heat duty: Precovered = mass_flow × cp × ΔTcoolant
2. Volume flow: volume_flow = mass_flow / density
3. Pump electricity: Ppump = Δpressure × volume_flow / ηpump
4. Heat exchanger: Precovered = U × A × ΔTlm
5. Buffer: energy = C × ΔTbuffer; participating mass = C/cp
ΔTlm = (ΔT1−ΔT2)/ln(ΔT1/ΔT2), with both terminal differences positive
Equal terminal differences → ΔTlm = that common difference
At cp=4000 J/(kg K) and coolant rise 50 K, 630 MW needs 3150 kg/s and 900 MW needs 4500 kg/s. With density 1000 kg/m³, pressure drop 0.5 MPa and pump efficiency 0.75, the corresponding pump loads are 2.1 and 3.0 MW. With assumed U=1000 W/(m² K) and log-mean approach 35 K, exchanger areas are 18,000 and 25,714 m². The pump allocation is a possible component of the existing “other loads”; add it only if it is absent there.
The example properties are placeholders, not a statement that water at any selected temperature/pressure is suitable. The exchanger approach is distinct from the primary-loop coolant temperature rise. Cycle efficiency must be reconciled with hot/cold reservoir temperatures and losses; reactor-node temperature or coolant return alone cannot establish it. ITER’s cooling-water overview describes separate machine and auxiliary heat-removal users.
Map a design allocation into the existing SINDA-style models
Design quantity
Model record / interpretation
Evidence needed
Participating thermal inventory
NODE capacity C=m cp [J/K]
Identify which material/fluid mass responds over the modeled timescale.
Contact or transfer path
CONDUCTOR G [W/K]; for simple conduction, G=k A/L
Effective path geometry, material properties and contact/film resistances.
Heat-removal path
SINK UA [W/K] to fixed return temperature
Boundary condition and effective transfer coefficient; this is not an explicit flow loop.
Fusion heat distribution
SOURCE fractions sum to one
Deposition allocation; avoid counting surface/divertor heat again in full recovered power.
Event or production source
ICF AVERAGE/PULSE; tokamak constant source
Time profile, repeated-event envelope or separate burn/dwell analysis.
The existing grid k=10⁸ W/(m K) is an effective system coupling, not a real solid conductivity. If UA=2×10⁷ W/K and U=1000 W/(m² K), their formal area equivalent is 20,000 m²; actual exchanger sizing still needs the terminal temperatures and approach. A refined grid cannot validate an unsupported material or transfer assumption.
Use the worksheet button to copy the current power-budget controls into the loaded thermal deck, then inspect and solve it. Sizes, flow and fuel estimates stay in the worksheet: assign NODE/CONDUCTOR/SINK values only after selecting the physical subsystem. The nine existing 1D/2D/3D models remain runnable. Compare time-step and grid refinements and inspect the energy residual.
Fuel processing, reserve and component lifetime
For D–T power, consumption follows the reaction-energy ledger. Circulating fuel can greatly exceed consumed fuel. Breeding, extraction, processing, storage and unburned recovery must each have a material boundary and residence time. ITER’s breeding overview describes the lithium blanket and fuel-replenishment interfaces.
Reaction energy Ef = 17.6 MeV × 1.602176634×10⁻¹³ J/MeV
Reaction rate = Pfusion/Ef
Consumed tritium mass flow = reaction rate × 5.008×10⁻²⁷ kg
Consumed T ≈ 0.15345 kg per GW-fusion full-power day
Circulating T flow ≈ consumed flow / single-pass burn fraction b
Processing hold-up ≈ circulating flow × processing residence time
Unburned recovery loss = (circulating flow − consumed flow)(1−ηrecovery)
Storage balance: dM/dt = recovered_unburned + extracted_bred + makeup
− injected − storage_losses − λM
λ = ln(2)/tritium_half_life
For a hypothetical 1 GW scenario, b=0.05 gives 3.069 kg T/day circulating flow. A 0.5-day processing residence implies 1.534 kg in that simplified processing stream alone. At unburned recovery efficiency 0.999, the unrecovered stream is approximately 0.00292 kg/day. This excludes blanket extraction hold-up, fixed equipment inventory, decay, reserve and start-up stock. At 700 MW, all these flow-proportional estimates are 0.7 times as large.
In a steady no-external-supply allocation, extracted breeding must cover consumed fuel, unrecovered losses and inventory decay; delays and downtime also matter. A breeding ratio above one by itself does not prove dynamic self-sufficiency. Reconcile processing-stream hold-up and reserve without counting the same inventory twice.
Maintenance and availability allocation
Energy exposure = ∫ assigned_component_power dt
Cycle exposure = count of specified thermal/mechanical cycles
Simple renewal availability estimate: A ≈ MTBF/(MTBF+MTTR)
Independent series subsystems only: Aplant ≈ product of subsystem availabilities
Annual scheduled-outage fraction = total nonoverlapping outage hours/8760
Six statistically independent series subsystems each at 0.95 availability give only 0.95⁶=0.735 overall. Shared cooling, power and scheduled outages violate that independence assumption; use a state/reliability model for the actual plant. Include inspection, cooling/warm-up, access, module removal, replacement, leak/alignment checks and recommissioning in repair time. Lifetime allocation needs neutron spectrum/fluence, irradiation damage, cyclic stress, erosion/corrosion and validated material data; neither MW-year nor cycle count alone qualifies a component.
Design closure and next-model checklist
Question to close
Next model or evidence
Acceptance quantities
Where does the energy go?
State-resolved source, thermal/fluid and electrical ledger
Source/removed/stored energy residual; each branch counted once.
Can the coolant remove it?
Flow network, exchanger correlations and component tests
Temperature, flow, pressure drop, pump electricity and transient margins.
Do components withstand the environment?
Neutronics, thermal-stress, irradiation and fatigue analysis
Spatial loads, degradation, qualified material limits and replacement interval.
Is fuel continuously available?
Delayed multi-compartment inventory model
Minimum stock, circulating flow, extraction/recovery losses and reserve.
Can the plant deliver the declared calendar output?
Integrated state/reliability and maintenance schedule
Burn/event duty, common-cause outages, replacement duration and annual export.
Are ignition and device physics supported?
Reactive plasma diagnostics plus device-specific validated analysis
Confinement/deposition losses and stability; ICF implosion or tokamak equilibrium/exhaust as appropriate.
Carry assumptions, units, uncertainty and source revision with every transferred quantity. Distinguish a calculated sizing allocation, an experimentally supported property and a verified requirement. Record the most sensitive coupled assumptions before selecting a preferred concept.
Requirements allocation and verification plan
The following is a draft traceability structure. Requirement owners must set numerical acceptance criteria and evidence maturity before a design review; no row claims a completed qualification.
ID
Proposed system requirement
Owner/interface
Verification method
Acceptance evidence to define
SYS-01
Export positive average net electrical energy under a declared scenario.
Grid connection
Power ledger + uncertainty sweep
Pnet, Paverage, GWh/year; all loads included.
SYS-02
Maintain a closed fuel inventory ledger across operating and outage states.
Fuel-cycle lead
Dynamic inventory model + integrated test
Production/recovery, losses, delay and reserve explicitly allocated.
SYS-03
Remove assigned heat in the normal state and defined loss-of-power states.
Thermal systems
Thermal-hydraulic analysis + component test
Heat duty, temperature, pressure and cooling continuity.
SYS-04
Provide observable operating state and independent protective actions.
Replace life-limited components within the availability allocation.
Maintenance
Service mock-up + schedule analysis
Access, replacement duration and spare readiness.
SYS-06
Trace material lifetime and containment requirements to the source environment.
Materials/confinement
Irradiation data + structural/containment analysis
Evidence for load cycles, neutron exposure and degradation.
ICF-01
Sustain the assumed usable event rate with the complete driver/chamber/target chain.
Driver + chamber + target supply
Integrated repetition campaign
Rate, readiness, unsuccessful events and component wear.
ICF-02
Achieve the driver electrical-efficiency allocation at the required duty.
Driver
Measured electrical-to-delivered energy test
Efficiency and cooling measured at operating rate.
Interface control records
For every interface, record the source and receiving subsystem, quantity, units, sign convention, reference boundary, normal range, transient envelope, timing, uncertainty, owner and revision. Separate a measured value from an assumed allocation. For example, blanket_to_power.heat_MW is positive into the power island; power_island_to_grid.net_MW is positive export after all electrical loads.
Design reviews
Concept review: mission, operating states, energy/fuel boundaries and candidate architecture.
Requirements review: traceable allocations, margins, interfaces and verification ownership.
Preliminary design: linked subsystem analyses, experimental evidence, uncertainty and serviceability.
Detailed design and integration: closed interfaces, qualified components, fault response and maintenance plans.
High gain with poor electrical efficiency can still import power.
Sweep gain and efficiency, then replace assumptions with jointly measured values.
Repetition-chain reliability
A driver that repeats rapidly does not prove the chamber or target supply can follow.
Demonstrate the complete chain with endurance and downtime accounting.
Pulsed chamber exposure and replaceable components
Average thermal power can hide pulse damage and maintenance constraints.
Separate pulse-response verification from average heat-removal verification.
Fuel reserve and processing delay
A positive power budget cannot supply fuel inventory.
Run a time-dependent material ledger with availability and losses.
Efficiency versus lifetime and availability
A favorable design point may require frequent replacement.
Include degradation, replacement outages and uncertain load allocations.
Record uncertain gain/Q, conversion efficiency, availability and load allocations separately. Sweep them jointly, avoid counting coupled benefits twice, and report ranges before selecting a preferred architecture.
Compare source/loss sensitivity to assumed confinement.
No tokamak equilibrium or ICF implosion.
5. Fuel depletion and ash
Verify consumed fuel, product energy and wall allocation.
Isolated Maxwellian node; no breeding or fuel processing.
6. Two-node heat transport
Check interface energy cancellation and projected diffusivity.
Prescribed transport; no blanket/neutron design.
Use the coupling workbench (sign-in required) to transfer declared heat sources into thermal/fluid/solid models. Preserve the volume conversion from W/m³ to W and account for each energy branch once. ICF target yield, compression and driver coupling require separate validated radiation-hydrodynamics and experimental evidence.
Reference context reviewed 10 October 2026. Equations and worked budgets on this page are transparent educational reductions. No preset represents an approved plant design or demonstrated commercial performance. The new dimensions, properties and component loads are illustrative allocations. Detailed target construction, qualified hardware specifications and equipment operating procedures require separate validated analyses. Independently verify consequential engineering results.
Level 2 · Blanket/coolant flow path and metal inventory
Carry the current system-level inputs into component sizing, then use explicit allocations to build native PDE inputs. The top worksheet remains the system budget.
Component equations and substitutions
Component results; SI units in quantity names
Level 3 · Native multi-node PDE worked examples
Use the existing SINDA-like PDE workbench. Thermal and structural models use native numbered-node decks; electric loss examples use numbered SINDA-like DC circuit records translated to the existing circuit calculator. Native beam, torsion and vacuum calculators extend the same protected workbench.
Sign-in required to run PDE calculations. The current editor is transferred in this tab and retained through sign-in. Select Import prepared engineering case, inspect panel 2, then Run combined model. Standalone verification and result downloads remain available in the workbench.
Each thermal case also has one fixed sink boundary. Native support and beam/shaft meshes are separate one-dimensional chains; the displayed thermal grid does not imply a 2D continuum structural solve.
Explicit active thermal nodes and lateral conductors. Every node also has a sink conductor.Editable native subsystem allocations
Changing the heat allocation overrides the default loss allocation in the native DC heater test. Native beam, shaft and vacuum parameters remain explicit in their individual decks and can be edited below.
1. Thermal: Ci dTi/dt = Qi + ΣGij(Tj−Ti) + UAi(Tsink−Ti).
Each supplied case finds a steady state using the existing thermal solver.
2. Electrical loss cases: native DC solve → I; heat = I² R.
Explicit SCALE/MAP ports allocate heat; CONSERVE checks their sum.
3. Thermal node temperature → native solid TEMP in kelvin.
The workbench converts native thermal degrees Celsius explicitly.
4. Axial support: Ku = F + Fthermal; εthermal=α(T−Treference).
5. Beam, where present: EI d4w/dx4=q, cubic Hermite FEM; each station
has transverse deflection w and slope θ.
6. Shaft, where present: −d(GJ dφ/dx)/dx = torque density;
circular-shaft shear τ=G r dφ/dx.
7. Vacuum, where present: Vi dpi/dt = Qi + ΣCij(pj−pi)−Si(pi−pbase).
Backward Euler; pressures are Pa and throughput is Pa m³/s.
8. Coolant, where present: Δp=R mdot; outlet rise Q/(mdot cp).
This separate coolant check uses the same design heat allocation.
Expected results for supplied baseline decks
Native steady thermal and support results; vacuum has a separate transient history
Active nodes
Maximum thermal temperature (K)
Maximum support displacement (m)
Native categories
3
587.967696
0.0186284534
THERMAL, SOLID, FLUID
5
586.810227
0.0188429257
THERMAL, SOLID, FLUID
9
587.967696
0.0186284534
THERMAL, SOLID, FLUID
References apply to the supplied default decks, not edited inputs. The linear thermal solution was checked independently; beam/torsion cases were compared with closed-form cantilever/shaft results, and vacuum throughput with its inventory balance. Refine the mesh or halve transient dt for changed models.
These are component models with declared material and boundary allocations. Thermal-to-solid transfer is one way; the separately evaluated coolant, beam, shaft and chamber checks do not form a synchronized full-system transient. Constant-property cold models do not establish a cryogenic material database or quantum-computer performance.
Define a mission, success criterion and operating environment before collecting evidence. The three required subsystem groups below contain six named component items. Series independence is an illustrative allocation; common-cause faults, redundancy, protective actions and dependencies require a corresponding fault tree or state model.
Illustrative test records, not measured field or qualification data. Priors at upper levels match the initial series allocation mean but have separately declared strength.
Appropriate evidence campaign: Component: optics, target and blanket/joint coupons. Subsystem: driver/injector timing and coolant-loop trials. System: repeatable shot campaigns meeting a declared pulse count and recovered-heat criterion; shots are not automatically independent complete plant missions.
How evidence changes each design level
Prior / early / mature example stages from left to right; green: part rollup, blue: subsystem-test rollup, brown: direct system evidence. Vertical position is reliability on a 0–1 scale; bars show 95% credible intervals. Seeded independent posterior sampling estimates product intervals.
More data increases evidence strength, but the estimated reliability can move down when failures appear. An early failure is useful evidence. Differences between part rollup, integration trials and mission trials reveal assumptions to revisit; they are not three independent reliability factors to multiply.
Zero-failure bounds versus prior-based credible intervals
Zero observed failures is not 100% demonstrated reliability. With n independent trials and no failures, the one-sided 95% binomial lower bound is 0.05^(1/n). With E total unit-hours and no constant-rate failures, the separate 95% upper rate bound is −ln(0.05)/E. These confidence bounds use different assumptions from Bayesian credible intervals.
Native PDE survivability calculation example
Open this study’s native physical baseline in PDE calculators. Load a completed native result to compare calculated maximum temperature and stress with the entered limits. Use the heat/mechanical factors to prepare a new native stress case; the existing solver workbench performs the physical calculation.
Loading the supplied native baseline…
The native factors are explicit independent sensitivity changes. They do not create a calibrated coupled hazard model. A thermal/stress limit check does not predict solder fatigue, radiation upset, magnet quench, corrosion, leakage, decoherence or other unmodeled modes. On PWB, a modeled body temperature also needs the separately stated internal junction-rise calculation when compared with a junction rating.
The constant-rate lifetime model does not describe cumulative wear-out or solder/bond/via fatigue without justification. Keep fixed-mission outcomes at matched age/cycle history, or fit a suitable censored lifetime/fatigue model. Hours and cycles are different exposure units; changing the lifetime mission duration does not transform the stored binary mission outcomes.
Conditional event survival and ordinary mission reliability
Environmental test outcomes estimate the conditional probability q of surviving a defined event severity. A Poisson count ν gives Senv(q)=exp[−ν(1−q)]. The displayed point uses posterior-mean q; a native margin is never silently converted to q. Combining Senv with ordinary mission reliability requires separate failure populations and independence. An event-triggered failure already counted in mission trials must not be counted again.
Equations and the path from assumptions to evidence
Binary mission success:
p ~ Beta(α,β); s successes and f failures → Beta(α+s,β+f).
Posterior mean = (α+s)/(α+β+s+f).
95% equal-tail credible interval uses Beta quantiles.
Independent required parts: Rsystem=∏Rpart; propagate posterior
uncertainty using separate component draws, not product endpoints.
Constant-rate lifetime evidence, a separate model:
λ ~ Gamma(shape a, rate b hours); r failures and E unit-hours
→ Gamma(a+r,b+E). Rate mean=(a+r)/(b+E) per hour.
Posterior predictive R(t)=E[exp(−λt)]=[(b+E)/(b+E+t)]^(a+r).
Parameter-uncertainty R bounds reverse the rate-quantile endpoints.
Total E includes right-censored survivors; it is not only failed-unit time.
Conditional survivability:
q posterior comes from comparable qualification outcomes.
Senv(q)=exp[−ν(1−q)] under independent Poisson events.
Physical model → temperature/stress margin; test likelihood → probability.
These are distinct steps and distinct uncertainty sources.
Concept / system level: write the mission boundary, failure definition, prior assumptions and allocated block structure. Simulation provides loads and possible failure modes, but does not create observed life data.
Part level: add matched-population coupon/component successes, failures, failure times and censored exposure. Update each part posterior. Retain material lot, geometry, assembly process, environment and failure-mode labels; the series rollup inherits these assumptions.
Subsystem level: test interfaces, cooling/power dependencies, controls and protective actions. Compare independent integration-trial posteriors with the part-based subsystem prediction. A gap can reveal assembly effects or common causes. Do not pool integration outcomes with reused part outcomes as if they were independent.
System level: use complete mission trials and field exposure under representative duty/environment. Compare the direct system posterior with lower-level rollups. A mission definition, repair policy, operating profile or design revision changes which data are exchangeable.
Physical calibration: use measured temperatures, strains, pressure or leak rates to update native material/interface/load inputs and their uncertainty, then rerun the PDE cases. Use actual failure/success observations for a reliability likelihood. A model-fit temperature correction is not itself a failure-rate observation.
Qualification / survival: record the event severity, exposure duration, pass criterion, conditioning history and surviving/failed units. Conditional survival applies to that envelope. Screening or destructive-limit tests are not automatically representative field-life trials.
Accelerated tests: convert exposure only with a validated failure-mode acceleration law. Store both raw and equivalent use-condition exposure. Temperature acceleration, cycle-fatigue and chemical degradation need different models; an Arrhenius factor is not a universal correction.
Review and update: show prior sensitivity, credible/confidence bounds, sample size and unresolved common-cause assumptions. Track design revisions and retests, avoid counting one event twice, and investigate early failures even when they lower the estimate.